In the summer, textile companies respond
[2018/6/26]   Clicks:[544]
 

In summer, many textile companies will cause equipment trips due to high temperature and many other problems, which will also affect the enthusiasm of workers while reducing production efficiency.

 

The countermeasures described below can effectively solve the situation of equipment jumping and enable textile companies to take precautions and stay safe.

 

First, the frequency changer

 

A large number of studies and practices have shown that the failure rate of the inverter will increase with the increase of temperature, and the service life will decrease with increasing temperature. With an ambient temperature of 10°C per liter, the service life of the inverter will be reduced by half.

 

The cause of the inverter overheating and the measures to solve it:

 

1, the ambient temperature is too high

 

Reason: When the inverter is working, it will generate a lot of heat, especially if the IGBT is working at high frequency, the heat will be more. If the ambient temperature is too high, the temperature of the internal components of the inverter may be too high. To protect the internal circuit of the inverter, the inverter will report a high temperature fault and shut down.

 

Countermeasures: Reduce the temperature of the place where the inverter is located. For example, you can add a forced cooling device such as an air conditioner or a fan to the cabinet.

 

2, fan stuck or damaged

 

Cause: When the inverter fan is bad, a large amount of heat accumulates inside the inverter and cannot be dispersed.

 

Countermeasure: Replace the fan.

 

3, poor ventilation of the inverter

 

Cause: If the air duct of the inverter is blocked or the air duct of the control cabinet is blocked, the heat dissipation inside the inverter will be affected, causing the inverter to overheat and alarm.

 

Countermeasures: Regularly check the frequency converter, remove the air from its air duct, and smooth the air duct.

 

4, overloaded

 

Countermeasures: Reduce the load or increase the capacity of the inverter.


 

How to reduce the frequency converter's failure rate and reduce losses:

 

1, summer frequency converter maintenance

 

Maintain proper temperature, humidity, ventilation, clean and non-interference, and regularly perform internal and external cleaning of the inverter.

 

2, the main aspects directly affect the cooling of the inverter

 

1) The built-in fan of the inverter is the main means of heat dissipation inside the cabinet, which will ensure the normal operation of the control circuit. Therefore, if the fan does not operate properly, it should be maintained immediately.

 

2) Overheat protection of the heat sink of the inverter module The inverter module is the main component of heat generation in the inverter and the most important and fragile component in the inverter. Therefore, each inverter is equipped with thermal protection devices on the heat sink.

 

3) Braking resistor overheat protection The nominal power of the braking resistor is selected according to short-time operation. Therefore, once the power-on time is too long, it will overheat. At this time, it should be suspended until it is cooled and then it can be used again, or you can use a resistor with a little more power.

 

4) The entrance and exit of the cooling air duct must not be blocked, and the ambient temperature may also be higher than the allowable value of the frequency converter. Some methods for solving the problems and suggestions for improvement have been put forward in a targeted manner, and there is a certain reference value for the application of the frequency converter in practical projects.

 

5) Interference issues Attention should be paid to the interference of the inverter to the microcomputer control board. The user's own design of the microcomputer control board has a poor level of technology and does not comply with EMC's international standards. After the inverter is used, the conduction and radiation interference generated often cause the control system to work abnormally and take necessary measures.

 

Second, the air compressor

 

If the air compressor oil cooler is clogged, the air compressor oil temperature will rise. A large part of the air compressor high temperature jumper is caused by the plugging of the air compressor oil cooler.

 

The main measures to avoid air compressor radiator jams are:

 

1, to prevent the air temperature in the station is too high

 

The role of air compressor oil in the screw air compressor is very important, that is, to be busy with lubrication, but also taking into account the seal, but also responsible for cooling. Therefore, the air compressor oil must be full, and the most direct reflection of the low oil level is that the air compressor has a high temperature and the machine trips. Have to be replaced in time, air compressor oil is not enough, look at the oil mirror to know. When shutting down, it should be between the lowest limit and the upper limit, preferably the upper point.

 

2, to prevent air compressor temperature control valve failure

 

Air compressor temperature control valve is an important component above the screw air compressor. It is equivalent to a brake. When the oil temperature has not yet come up when the air compressor is just turned on, he is turned off. The air compressor lubricant is gone. The small cycle, that is, does not flow through the cooler; when the oil temperature comes up, the temperature probe inside it opens, and the oil goes to the big cycle and flows through the cooler to the head. Keep the air compressor oil at a normal oil temperature. If the air compressor thermostatic valve fails, the temperature probe cannot be opened at the top, then the screw air compressor will cause high temperature failure.

 

3, to prevent air compressor oil filter and air filter clogging

 

The air filter of the air compressor must be kept unobstructed at all times. When the dust is used in large working conditions, the air filter should always use compressed air to clean the dust on it, otherwise the air intake channel will not be smooth, and it will affect the screw air compressor. Normal operation; If the air compressor oil filter is blocked, it will cause the lubricating oil road to be unobstructed, and the amount of oil entering the main engine will be less. The high-temperature shutdown fault will also occur.


Keywords:High-strength polyester fiber  Multi-strand ropes Polypropylene Sesi Anti-aging polypropylene yarn Strong resistance to stretchin
Relevant:
   What are the main uses of poly    Breakthroughs in the research
   Textile and garment industry w    How is polypropylene high stre
   Jiangsu Silk Edge Fiber Co., L    【 Silk edge news 】 Leadership
   Textile industry leads new qua    Polypropylene engineering fibe
   High strength polypropylene wi    Operation analysis of China's
Top:
Polypropylene monofilament fiber
Polypropyl
Clover polypropylene fibers
Clover pol
Polypropylene fiber works
Polypropyl
Polypropylene Sesi
Polypropyl
Keyword :High-strength polyester fiber  Multi-strand ropes Polypropylene Sesi Anti-aging polypropylene yarn Strong resistance to stretchin
Keyword: 工程纤维 | 高强丙纶丝 | 高强丙纶线 | 聚丙烯纤维 | 聚酯纤维 | 纤维素纤维 | 聚丙烯网状纤维 | 墙衣纤维 | 木质素纤维 | 高强倍捻丙纶长丝 |
Hot link: 龙马色母粒 | 蓝景纳米材料 | 东华纺丝机 | 金彩新材料 | 丝丝缘网上商城 | 浩凯化纤 | 宏特化纤 | 倍联现代物流 |
Address:No. 1 HaiDu North road Sheyang Economic development zone, Jiangsu province TEL:0086-0515-82312319 82312488 FAX:0086-0515-82338366
Copyright 江苏丝丝缘纤维有限公司